2nd Generation Broadband Over Power Line Edge Interface

TI BPL2 EDGE B and SIU INTERFACE

Go to Product Support
product image

• Connects zone outputs from BPL2 sensors and/or Power Line (PL) sensors to a controller, providing power and communications to BPL2 sensors and/or PL sensors
• Connects PC to the BPL2 sensors and/or PL sensors for system configuration & viewing
• Maximum number of cameras: Four BPL2 or PL sensors
• Compatible BPL2 Sensor(s): ThermiCam2, TrafiCam X-Stream2, TrafiSense 2
• Compatible PL Sensor(s): TrafiOne
• Recommended maximum of up to four BPL2/PL sensors

Specifications
Communications
Connector
Cable BPL2 Sensor – Interface:
3 × wires via clamps (back):
2 × wires for DC power & communication: broadband over power line (BPL) and 1 × wire for functional earth

Interface Mounting:
EDGE-rack mountable
Ethernet
2 × RJ45 Ethernet connectors (10/100 Mbit/s auto switching)
Input
C12S connector available on the front for SIU to ATC controller
4 × optical coupled dry contacts via EDGE connector (back, pins F/H, W/X, S/T, Y/Z)
Imax = 50 mA, Umax = 48 V DC
Close on event or open on event (setting in software)
4 × output LEDs (front, green)
Detection output 1 to 4 and common detection output 1 to 4
4 × input contacts via EDGE connector (back, pins 1, 2, 3, 10)
4 × input LEDs (front, green)
Note: maximum 20 extra detection outputs can be added via maximum five 4 I/O USB units
Output
Detection Outputs:
64 × output states via Port-1 connector (front, SDLC) to TS-2/ATC controller

Error Outputs:
1 × optical isolated switch component via EDGE connector (back, pins J/K) - Imax = 50 mA, Umax = 48 V DC
Open on event (hardware output)
8 × BPL2 sensor status LEDs (front, bicolor green/red)
Error output and common error output

Function of Error Output:
Error output active = error in TI BPL2 EDGE B&SIU or power supply down, or
Error output active = error in 4 I/O USB with output(s) assigned (e.g. no communications), or
Error output active = error in corresponding BPL2 sensor (e.g. no communications)
Electrical
Power
Power IN:
12 V DC to 60 V DC, via EDGE connector (back, pins A/B, polarity sensitive), power button and LED (front, bicolor green/red) Separate 24VDC to 48 V DC via EDGE connector (back, pins D/E) for BPL2 sensors Note: 48 V DC on pins D/E recommended when multiple BPL2 sensors and/or long cable distances
Power OUT:
Idem power IN, via EDGE connector (back, pins P/R, polarity insensitive)
Note: BPL2 communications to BPL2 sensors added at interface level)

Power Consumption:
Interface only: typical ≤5 W (6 W peak at start-up)
Maximum, interface with periphery: <100 W @ 24 V DC

Current Consumption:
Interface only: typical ≤210 mA @ 24 V DC
Maximum, interface with periphery: <4 A @ 24 V DC
Environmental
Operating Temperature Range
NEMA II specs: -34°C to 74°C (-29.2°F to 165.2°F)
Shock & Vibration
FCC: FCC Part 15 class B
Shock & Vibration NEMA II specs
Mechanical
Dimensions
H × W × D: 115 mm × 59 mm × 191 mm (4.53 in × 2.32 in × 7.52 in) Standard US EDGE rack height & depth; width = double slot
Weight
450 g (1 lb)
Related Documents
Export Restrictions

Export Restrictions

The information contained in this page pertains to products that may be subject to the International Traffic in Arms Regulations (ITAR) (22 C.F.R. Sections 120-130) or the Export Administration Regulations (EAR) (15 C.F.R. Sections 730-774) depending upon specifications for the final product; jurisdiction and classification will be provided upon request.